Resultados 1 - 20 de 2.331
Filtrar
1.
Transl Vis Sci Technol ; 13(4): 3, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564201

RESUMO

Purpose: The purpose of this study was to evaluate the effects of posterior vitreous detachment (PVD) on visual quality in patients with high myopia, as well as investigate the associated factors of photopic and mesopic contrast sensitivity function (CSF) in high myopia. Methods: Visual quality was comprehensively assessed in patients with high myopia. Visual acuity, contrast sensitivity (CS) at four spatial frequencies (3, 6, 12, and 18 cycles per degree [c.p.d.]) under photopic and mesopic conditions, as well as the modulation transfer function cutoff value (MTFcutoff), the objective scatter index (OSI), the Strehl ratio (SR), and internal aberrations, were measured in this cross-sectional study. Results: This study included 94 eyes from 47 subjects with bilateral high myopia, including 23 eyes with complete PVD (cPVD), 21 eyes with partial PVD (pPVD), and 50 eyes without PVD (nPVD). There was no significant difference in visual quality between the cPVD group and the nPVD group. Whereas in eyes with pPVD, there was a degradation of overall photopic CSF (versus nPVD, P = 0.048), photopic CS at 3 c.p.d. (versus cPVD, P = 0.009 and versus nPVD, P = 0.032), photopic CS at 18 c.p.d. (versus nPVD, P = 0.033), overall mesopic CSF (versus nPVD, P = 0.033), and secondary astigmatism (versus cPVD, P = 0.044). Under photopic conditions, the factors affecting CSF were pPVD and SR, whereas the factors affecting mesopic CSF were pPVD, OSI, and ganglion cell-inner plexiform layer thickness. Conclusions: The pPVD impaired visual quality in patients with high myopia compared to nPVD or cPVD, and pPVD could be a factor explaining CSF at both photopic and mesopic illumination. Translational Relevance: Clinicians need to closely monitor patients with high myopia with pPVD due to the potential decline in visual quality and the development of vitreoretinal disorders.


Assuntos
Miopia , Descolamento do Vítreo , Humanos , Sensibilidades de Contraste , Estudos Transversais , Miopia/complicações , Miopia/diagnóstico , Retina
2.
Invest Ophthalmol Vis Sci ; 65(4): 14, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38578621

RESUMO

Purpose: This study aims to examine the short-term peripheral choroidal thickness (PChT) response to signed defocus blur, both with and without native peripheral aberrations. This examination will provide insights into the role of peripheral aberration in detecting signs of defocus. Methods: The peripheral retina (temporal 15°) of the right eye was exposed to a localized video stimulus in 11 young adults. An adaptive optics system induced 2D myopic or hyperopic defocus onto the stimulus, with or without correcting native peripheral ocular aberrations (adaptive optics [AO] or NoAO defocus conditions). Choroidal scans were captured using Heidelberg Spectralis OCT at baseline, exposure (10, 20, and 30 minutes), and recovery phases (4, 8, and 15 minutes). Neural network-based automated MATLAB segmentation program measured PChT changes from OCT scans, and statistical analysis evaluated the effects of different optical conditions over time. Results: During the exposure phase, NoAO myopic and hyperopic defocus conditions exhibited distinct bidirectional PChT alterations, showing average thickening (10.0 ± 5.3 µm) and thinning (-9.1 ± 5.5 µm), respectively. In contrast, induced AO defocus conditions did not demonstrate a significant change from baseline. PChT recovery to baseline occurred for all conditions. The unexposed fovea did not show any significant ChT change, indicating a localized ChT response to retinal blur. Conclusions: We discovered that the PChT response serves as a marker for detecting peripheral retinal myopic and hyperopic defocus blur, especially in the presence of peripheral aberrations. These findings highlight the significant role of peripheral oriented blur in cueing peripheral defocus sign detection.


Assuntos
Hiperopia , Miopia , Adulto Jovem , Humanos , Miopia/diagnóstico , Hiperopia/diagnóstico , Corioide , Retina , Fóvea Central , Refração Ocular
3.
Transl Vis Sci Technol ; 13(4): 17, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38591943

RESUMO

Purpose: To characterize the fundus tessellated density (FTD) in highly myopic glaucoma (HMG) and high myopia (HM) for discovering early signs and diagnostic markers. Methods: This retrospective cross-sectional study included hospital in-patients with HM (133 eyes) and HMG (73 eyes) with an axial length ≥26 mm at Zhongshan Ophthalmic Center. Using deep learning, FTD was quantified as the average exposed choroid area per unit area on fundus photographs in the global, macular, and disc regions. FTD-associated factors were assessed using partial correlation. Diagnostic efficacy was analyzed using the area under the curve (AUC). Results: HMG patients had lower global (0.20 ± 0.12 versus 0.36 ± 0.09) and macular FTD (0.25 ± 0.14 vs. 0.40 ± 0.09) but larger disc FTD (0.24 ± 0.11 vs. 0.19 ± 0.07) than HM patients in the tessellated fundus (all P < 0.001). In the macular region, nasal FTD was lowest in the HM (0.26 ± 0.13) but highest in the HMG (0.32 ± 0.13) compared with the superior, inferior, and temporal subregions (all P < 0.05). A fundus with a macular region nasal/temporal (NT) FTD ratio > 0.96 (AUC = 0.909) was 15.7 times more indicative of HMG than HM. A higher macular region NT ratio with a lower horizontal parapapillary atrophy/disc ratio indicated a higher possibility of HMG than HM (AUC = 0.932). Conclusions: FTD differs in degree and distribution between HMG and HM. A higher macular NT alone or with a lower horizontal parapapillary atrophy/disc ratio may help differentiate HMG. Translational Relevance: Deep learning-based FTD measurement could potentially assist glaucoma diagnosis in HM.


Assuntos
Aprendizado Profundo , Demência Frontotemporal , Glaucoma , Miopia , Humanos , Estudos Transversais , Estudos Retrospectivos , Glaucoma/complicações , Glaucoma/diagnóstico , Miopia/complicações , Miopia/diagnóstico , Atrofia , Corioide
5.
BMC Ophthalmol ; 24(1): 186, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654225

RESUMO

BACKGROUND: Among sex chromosome aneuploidies, 48, XXYY syndrome is a rare variant. This condition is marked by the existence of an additional X and Y chromosome in males, leading to a diverse range of physical, neurocognitive, behavioral, and psychological manifestations. Typical characteristics include a tall stature and infertility. Other phenotypes include congenital heart defects, skeletal anomalies, tremors, obesity, as well as the potential for type 2 diabetes and/or peripheral vascular disease. CASE PRESENTATION: A 6-year-old boy, who had been experiencing progressive vision deterioration in both eyes for the past two years, presented with a history of poor vision, delayed motor skills. The patient was diagnosed with micropenis in the pediatric outpatient clinic. Sparse hair, an unusually tall stature and craniofacial dysmorphology characterized by ocular hypertelorism, depressed nasal bridge, and epicanthic folds were observed. Comprehensive ophthalmic examination revealed high myopia and grade 3 macular hypoplasia. Diagnostic investigations including karyotype analysis and whole-exome sequencing identified an anomalous male karyotype comprising two X and two Y chromosomes, confirming a diagnosis of 48, XXYY syndrome. CONCLUSIONS: This study underscores the rare association of high myopia and grade 3 macular dysplasia with 48, XXYY syndrome. To our knowledge, this case marks the first recorded instance of macular dysplasia in a patient with 48, XXYY syndrome. This novel finding enhances our understanding of this syndrome's phenotypic variability.


Assuntos
Macula Lutea , Humanos , Masculino , Criança , Macula Lutea/patologia , Macula Lutea/anormalidades , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/genética , Miopia Degenerativa/complicações , Síndrome de Klinefelter/diagnóstico , Síndrome de Klinefelter/genética , Síndrome de Klinefelter/complicações , Miopia/genética , Miopia/diagnóstico , Miopia/complicações
6.
BMC Ophthalmol ; 24(1): 182, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649848

RESUMO

BACKGROUND: The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia. METHODS: The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA). RESULTS: The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed. CONCLUSIONS: The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.


Assuntos
Segmento Anterior do Olho , Córnea , Topografia da Córnea , Miopia , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Adulto , Miopia/diagnóstico , Miopia/fisiopatologia , Topografia da Córnea/métodos , Topografia da Córnea/instrumentação , Reprodutibilidade dos Testes , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Adulto Jovem , Córnea/diagnóstico por imagem , Córnea/patologia , Pessoa de Meia-Idade , Biometria/métodos , Adolescente , Estudos Prospectivos
7.
Invest Ophthalmol Vis Sci ; 65(4): 22, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38597724

RESUMO

Purpose: Studies report conflicting findings regarding choroidal thickness changes in response to myopic defocus in humans. This study aimed to investigate the choroidal response to myopic defocus in children and adults using automated analysis. Methods: Participants (N = 46) were distance-corrected in both eyes and viewed a movie on a screen for 10 minutes. Two optical coherence tomography (OCT) radial scans were collected for each eye, then +3 diopters was added to one eye. Participants continued to watch the movie, OCT scans were repeated every 10 minutes for 50 minutes, and then recovery was assessed at 60 and 70 minutes. Defocus was interrupted for approximately two out of each 10 minutes for OCT imaging. OCT images were analyzed using an automated algorithm and trained neural network implemented in MATLAB to determine choroidal thickness at each time point. Repeated-measures ANOVA was used to assess changes with time in three age groups (6-17, 18-30, and 31-45 years) and by refractive error group (myopic and nonmyopic). Results: Choroidal thickness was significantly associated with spherical equivalent refraction, with the myopic group having a thinner choroid than the nonmyopic group (P < 0.001). With imposed myopic defocus, there were no significant changes in choroidal thickness at any time point for any age group and for either refractive error group (P > 0.05 for all). Conclusions: Findings demonstrate that, using the described protocol, the choroidal thickness of children and adults does not significantly change in response to short-term, full-field myopic defocus, in contrast to several previously published studies.


Assuntos
Miopia , Erros de Refração , Adulto , Criança , Humanos , Miopia/diagnóstico , Corioide , Refração Ocular , Tomografia de Coerência Óptica
8.
Ann Med ; 56(1): 2331056, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38507901

RESUMO

OBJECTIVES: To analyze the factors influencing myopia and construct a nomogram to forecast the risk of myopia among school-age children, providing a reference for identifying high-risk groups to aid prevention and control. METHODS: This case-control study enrolled 3512 students from three primary schools in Shenzhen using random cluster sampling for a questionnaire survey, myopia screening and ocular biometric parameter measurement. Logistic regression was used to analyze the influencing factors of myopia, and a nomogram was constructed to forecast myopia risk. Bootstrap resampling was used to verify the practicability of the nomogram. RESULTS: Older age (odds ratio[OR] = 1.164; 95% confidence interval [CI]: 1.111-1.219), female sex (OR = 2.405; 95% CI: 2.003-2.887), maternal myopia (OR = 1.331; 95% CI: 1.114-1.589), incorrect posture during reading and writing (OR = 1.283; 95% CI: 1.078-1.528) and axial length (OR = 7.708; 95% CI: 6.044-8.288) are risk factors for myopia, whereas an increase in corneal radius (OR = 0.036; 95% CI: 0.025-0.052) is a protective factor against myopia. The area under the receiver operating characteristic (ROC) curve of the nomogram was 0.857, and the net benefit was high when the risk threshold of the decision curve analyses (DCA) ranged from 0.20 to 1.00. The measured values were consistent with the prediction. CONCLUSION: The nomogram was accurate in predicting the risk of myopia among schoolchildren. This study provides a reference for screening high-risk students and for individualized myopia prevention and control.


Older age, female sex, maternal myopia, incorrect posture during reading and writing, and prolonged axial length are risk factors for myopia among primary school students.The nomogram constructed based on age, sex, maternal myopia, incorrect posture during reading and writing, axial length and corneal radius showed good predictive accuracy and practicability.The nomogram constructed in this study can be used for individualized myopia risk assessment.


Assuntos
Miopia , Nomogramas , Criança , Humanos , Feminino , Estudos de Casos e Controles , Estudantes , Fatores de Risco , Miopia/diagnóstico , Miopia/epidemiologia , Miopia/prevenção & controle
9.
J Transl Med ; 22(1): 289, 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38494492

RESUMO

BACKGROUND: Global myopia prevalence poses a substantial public health burden with vision-threatening complications, necessitating effective prevention and control strategies. Precise prediction of spherical equivalent (SE), myopia, and high myopia onset is vital for proactive clinical interventions. METHODS: We reviewed electronic medical records of pediatric and adolescent patients who underwent cycloplegic refraction measurements at the Eye & Ear, Nose, and Throat Hospital of Fudan University between January 2005 and December 2019. Patients aged 3-18 years who met the inclusion criteria were enrolled in this study. To predict the SE and onset of myopia and high myopia in a specific year, two distinct models, random forest (RF) and the gradient boosted tree algorithm (XGBoost), were trained and validated based on variables such as age at baseline, and SE at various intervals. Outputs included SE, the onset of myopia, and high myopia up to 15 years post-initial examination. Age-stratified analyses and feature importance assessments were conducted to augment the clinical significance of the models. RESULTS: The study enrolled 88,250 individuals with 408,255 refraction records. The XGBoost-based SE prediction model consistently demonstrated robust and better performance than RF over 15 years, maintaining an R2 exceeding 0.729, and a Mean Absolute Error ranging from 0.078 to 1.802 in the test set. Myopia onset prediction exhibited strong area under the curve (AUC) values between 0.845 and 0.953 over 15 years, and high myopia onset prediction showed robust AUC values (0.807-0.997 over 13 years, with the 14th year at 0.765), emphasizing the models' effectiveness across age groups and temporal dimensions on the test set. Additionally, our classification models exhibited excellent calibration, as evidenced by consistently low brier score values, all falling below 0.25. Moreover, our findings underscore the importance of commencing regular examinations at an early age to predict high myopia. CONCLUSIONS: The XGBoost predictive models exhibited high accuracy in predicting SE, onset of myopia, and high myopia among children and adolescents aged 3-18 years. Our findings emphasize the importance of early and regular examinations at a young age for predicting high myopia, thereby providing valuable insights for clinical practice.


Assuntos
Miopia , Refração Ocular , Adolescente , Criança , Humanos , Miopia/diagnóstico , Miopia/epidemiologia , Pré-Escolar
10.
Invest Ophthalmol Vis Sci ; 65(3): 17, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38470328

RESUMO

Purpose: To evaluate the longitudinal changes in subfoveal choroidal thickness (SFCT) in children with different refractive status. Methods: A total of 2290 children 3 to 14 years old who attended the first year of kindergarten (G0), first year of primary school (G1), fourth year of primary school (G4), or first year of junior high school (G7) in Guangzhou, China, were recruited and followed up for 2 years. All participants received cycloplegic autorefraction, axial length measurement and SFCT measurement using a CIRRUS HD-OCT device. Children were divided into groups of persistent non-myopia (PNM), persistent myopia (PM), or newly developed myopia (NDM). Children in the PNM and PM groups were further divided into subgroups of stable refraction (absolute mean annual spherical equivalent refraction [SER] change < 0.5 D) and refractive progression (absolute mean annual SER change ≥ 0.5 D). Results: The mean ± SD ages for the G1 to G7 cohorts were 3.89 ± 0.30, 6.79 ± 0.47, 9.71 ± 0.34, and 12.54 ± 0.38, years, respectively. SFCT consistently decreased in the NDM group across the G1 to G7 cohorts (all P < 0.001) and exhibited variability across different age cohorts in the PNM and PM groups. Further subgroup analysis revealed significant thickening of SFCT in the PNM-stable group among the G0, G1, and G7 cohorts (all P < 0.05), whereas it remained stable among all cohorts in the PM-stable group (all P > 0.05). Conversely, SFCT exhibited thinning in the G4 and G7 cohorts in the PM-progressive group (both P < 0.01) and for the entire cohort of children in the PNM-progressive group (P = 0.012). Conclusions: SFCT increased in nonmyopic children with stable refraction, remained stable in myopic children maintained stable refraction, and decreased in those with refractive progression, whether they were myopic or not.


Assuntos
Miopia , Testes Visuais , Criança , Humanos , Pré-Escolar , Adolescente , Estudos de Coortes , Refração Ocular , China , Miopia/diagnóstico
11.
BMC Ophthalmol ; 24(1): 117, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481187

RESUMO

BACKGROUND: To report a case of interface fluid syndrome (IFS) following traumatic corneal perforation repair after small incision lenticule extraction (SMILE). CASE PRESENTATION: A 23-year-old woman, with a past history of SMILE, was struck in the left eye with a barbecue prod and subsequently underwent corneal perforation repair at local hospital. Primary wound repaired with a single 10 - 0 nylon suture at the area of leakage. After the surgery, her best corrected visual acuity (BCVA) was 20/30. Four days later, she presented at our hospital with blurred vision, and interface fluid syndrome (IFS) was diagnosed. Intraoperative optical coherence tomography (iOCT) was used to guide the resuturing of the corneal perforation in the left eye, followed by anterior chamber gas injection. At the first postoperative month, the BCVA was 20/25. The corneal cap adhered closely to the stroma, the surface became smooth. CONCLUSIONS: This case illustrates that any corneal perforation following lamellar surgery, including SMILE, may lead to IFS. It is crucial to consider the depth of corneal perforation, and intraoperative optical coherence tomography (iOCT) plays a unique role in the repair procedure.


Assuntos
Perfuração da Córnea , Cirurgia da Córnea a Laser , Miopia , Humanos , Feminino , Adulto Jovem , Adulto , Perfuração da Córnea/diagnóstico , Perfuração da Córnea/etiologia , Perfuração da Córnea/cirurgia , Miopia/cirurgia , Miopia/diagnóstico , Substância Própria/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Córnea , Tomografia de Coerência Óptica/métodos , Cirurgia da Córnea a Laser/efeitos adversos , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea , Lasers de Excimer
12.
Indian J Ophthalmol ; 72(4): 549-553, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546469

RESUMO

PURPOSE: To compare the accuracy of nine conventional and newer-generation formulae in calculating intraocular lens power in eyes with axial myopia. SETTING: Tertiary eye care center, Bengaluru, India. DESIGN: Retrospective cross-sectional, comparative study conducted in India. METHODS: Patients undergoing uneventful phacoemulsification in eyes with axial length >26 mm were included. Preoperative biometry was done using Lenstar LS 900 (Haag-Streit AG, Switzerland). Single eye of patients undergoing bilateral implantation was randomly selected. Optimized lens constants were used to calculate the predicted postoperative refraction of each formula, which was then compared with the actual refractive outcomes to give the prediction errors, following which subgroup analysis was performed. The Kane formula, Barrett universal II, Emmetropia Verifying Optical (EVO) 2.0, Hill Radial Basis Function (Hill RBF) 3.0, Olsen formula, along with Wang Koch-adjusted four formulae, that is, Sanders Retzlaff Kraff/Theoretical (SRK/T), Holladay 1, Haigis, and Hoffer Q formula, were compared for intraocular lens power calculations. RESULTS: One hundred and sixty-five eyes that fulfilled all the inclusion criteria were studied. Hill RBF 3.0 had the lowest mean and median absolute prediction errors (0.355 and 0.275, respectively) compared to all formulas. In subgroup analysis (26-28, >28-30, and >30 mm), significant difference was seen only in extremely long eyes (>30 mm). The Hill RBF 3.0 formula generated the maximum percentage of eyes with refractive errors within ±0.25, ±0.5, ±0.75, and ±1 D (46%, 76.2%, 89.9%, and 95.8%, respectively). CONCLUSION: This is the first study evaluating all the formulas exclusively in the myopic eyes. Hill RBF 3 was found to be superior in accuracy to all other formulas.


Assuntos
Lentes Intraoculares , Miopia , Humanos , Estudos Transversais , Estudos Retrospectivos , Olho , Miopia/diagnóstico , Miopia/cirurgia
14.
Comput Biol Med ; 172: 108281, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38503096

RESUMO

BACKGROUND AND OBJECTIVE: The prevalence of myopia and high myopia is increasing globally, underscoring the growing importance of diagnosing high myopia-related pathologies. While existing image segmentation models, such as U-Net, UNet++, ResU-Net, and TransUNet, have achieved significant success in medical image segmentation, they still face challenges when dealing with ultra-widefield (UWF) fundus images. This study introduces a novel automatic segmentation algorithm for the optic disc and peripapillary atrophy (PPA) based on UWF fundus images, aimed at assisting ophthalmologists in more accurately diagnosing high myopia-related diseases. METHODS: In this study, we developed a segmentation model leveraging a Transformer-based network structure, complemented by atrous convolution and selective boundary aggregation modules, to elevate the accuracy of segmenting the optic disc and PPA in UWF photography. The atrous convolution module adeptly manages multi-scale features, catering to the variances in target sizes and expanding the deep network's receptive field. Concurrently, the incorporation of the selective boundary aggregation module in the skip connections of the model significantly improves the differentiation of boundary information between segmentation targets. Moreover, the comparison of our proposed algorithm with classical segmentation models like U-Net, UNet++, ResU-Net, and TransUNet highlights its considerable advantages in processing UWF photographs. RESULTS: The experimental results show that, compared to the other four models, our algorithm demonstrates substantial improvements in segmenting the optic disc and PPA in UWF photographs. In PPA segmentation, our algorithm improves by 0.8% in Dice, 1.8% in sensitivity, and 1.3% in intersection over union (IOU). In optic disc segmentation, our algorithm improves by 0.3% in Dice, 0.6% in precision, and 0.4% in IOU. CONCLUSION: Our proposed method improves the segmentation accuracy of PPA and optic disks based on UWF photographs, which is valuable for diagnosing high myopia-related diseases in ophthalmology clinics.


Assuntos
Miopia , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Disco Óptico/patologia , Fundo de Olho , Algoritmos , Miopia/diagnóstico , Miopia/patologia , Atrofia/patologia , Processamento de Imagem Assistida por Computador
15.
Korean J Ophthalmol ; 38(2): 137-146, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38449306

RESUMO

PURPOSE: To investigate the relationship between myopia and obesity through direct measurements of fat content. METHODS: A cross-sectional study used a stratified, multistage survey, the Korea National Health and Nutrition Examination Survey (2008-2010). Subjects 19 years or older (n = 10,305) were included. Participants were divided into three groups according to refractive status: myopia (spherical equivalent [SE] ≤ -1.0 diopter [D]), emmetropia (-1.0 D < SE ≤ 1.0 D), and hyperopia (SE > 1.0 D). Obesity was investigated with assessment of fat mass and body mass index or waist circumference. Fat mass was measured with whole-body dual energy x-ray absorptiometry. Body fat percentage was calculated as (total fat mass / body weight × 100). RESULTS: Higher obesity index was found in individuals with myopic eyes after adjustment for age, sex, education level, income status, physical activity, residence, and serum vitamin D level. The significant difference in total body fat percentages among myopia, emmetropia, and hyperopia was significant in the young age group (19-39 years, p < 0.05) but not in the middle age group (40-64 years) and the old age group (≥65 years). Individuals with a higher percentage of total body fat had greater odds ratios for myopia (fourth quartile of body fat; odds ratio, 1.352; 95% confidence interval, 1.178-1.551). CONCLUSIONS: An association was found between adiposity and myopia in relatively young adults using direct measurements of fat mass.


Assuntos
Hiperopia , Miopia , Pessoa de Meia-Idade , Adulto Jovem , Humanos , Adulto , Idoso , Inquéritos Nutricionais , Estudos Transversais , Obesidade/complicações , Obesidade/diagnóstico , Obesidade/epidemiologia , Miopia/diagnóstico , Miopia/epidemiologia
16.
Ophthalmic Physiol Opt ; 44(3): 525-536, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38456753

RESUMO

OBJECTIVE: To compare large- and medium-sized choroidal vascularity and the choriocapillaris (CC) flow area in children with different refractive errors using swept-source optical coherence tomography angiography (SS-OCTA). METHODS: Forty-two anisometropic children were enrolled and divided into hyperopic anisometropia (HA) and myopic anisometropia (MA) groups. SS-OCTA was performed to analyse choroidal vascularity. Mean choroidal thickness (CT), choroidal vascularity volume (CVV), choroidal vascularity index (CVI) and CC flow area were compared between the two eyes. The inter-ocular differences between the two groups were also determined. RESULTS: Mean CT and CVV were highest in eyes with shorter axial lengths in both refractive groups, and the difference between the two eyes was positively correlated with the difference in axial length at the foveal region. Significant differences in the CVI in the MA group were only found in the parafoveal region. Inter-ocular differences in the CC were significantly reduced in eyes with longer axial lengths in the foveal and parafoveal regions of the HA and MA groups, respectively. Comparing inter-ocular differences, CC was significantly greater in the parafoveal region of the MA group than the HA group. CONCLUSIONS: All layers of choroidal vasculature were thinner in eyes with longer axial lengths in all groups. The inter-ocular CC difference was greater in the MA than in the HA group, with similar differences in axial length. This suggests that both medium-to-large choroidal vascular and choroidal capillaries may play a role in myopia development.


Assuntos
Anisometropia , Hiperopia , Miopia , Erros de Refração , Criança , Humanos , Tomografia de Coerência Óptica/métodos , Miopia/diagnóstico , Corioide
17.
Int Ophthalmol ; 44(1): 153, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509410

RESUMO

PURPOSE: This study aimed to measure the Raman spectrum of the human corneal stroma lens obtained from small incision lenticule extraction surgery (SMILE) in Asian myopic eyes using a confocal Raman micro-spectrometer built in the laboratory. METHODS: Forty-three myopic patients who underwent SMILE with equivalent diopters between - 4.00 and - 6.00 D were selected, and the right eye data were collected. Corneal stroma lenses were obtained during surgery, and the Raman spectra were measured after air drying. The complete Raman spectrum of human myopic corneal stroma lens tissue was obtained within the range of 700-4000 cm-1. RESULTS: Thirteen characteristic peaks were found, with the stronger peaks appearing at 937 cm-1, corresponding to proline, valine, and the protein skeleton of the human myopic corneal stroma lens; 1243 cm-1, corresponding to collagen protein; 1448 cm-1, corresponding to the collagen protein and phospholipids; and 2940 cm-1, corresponding to the amino acid and lipids, which was the strongest Raman peak. CONCLUSION: These results demonstrated that Raman spectroscopy has much potential as a fast, cost-effective, and reliable diagnostic tool in the diagnosis and treatment of eye diseases, including myopia, keratoconus, and corneal infection.


Assuntos
Cirurgia da Córnea a Laser , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Substância Própria/cirurgia , Acuidade Visual , Miopia/diagnóstico , Miopia/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Colágeno , Lasers de Excimer , Refração Ocular
18.
J. optom. (Internet) ; 17(1)Jan.-March. 2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-229118

RESUMO

Purpose Myopia is a growing pandemic, especially in children, who risk low vision later in life. Home confinement during the COVID-19 pandemic may have increased myopia progression through increased screentime, decreased time outdoors and increased near work activities. The aim of this study is to compare progression of myopia in children during home confinement period in the COVID-19 pandemic with pre-COVID-19 progression. Methods On January 2023 PubMed, EMBASE and Cochrane were searched for relevant studies. Studies meeting the following criteria were eligible for inclusion: children (under 18 years), home confinement due to COVID-19, spherical equivalent refractive (SER) and axial length (AL) measurements and a follow-up period to measure progression. Quality appraisal was performed by two reviewers independently using the Joanna Briggs Institute tool for cohort studies. Outcomes for myopia were assessed through meta-analysis, analyzing SER (random effects) and AL (fixed effects). Results Hundred and two articles were identified in the search, of which five studies were included in the analysis. Risk of bias is moderate with a few critical flaws in the studies. Myopia progressed more rapidly during the COVID-19 pandemic compared to the pre-COVID-19 period, both in terms of SER (-0.83D [95 %CI, −1.22, −0.43] and AL (0.36 mm [95 %CI, 0.13, 0.39]). Conclusion Progression of myopia during the COVID-19 pandemic accelerated more rapidly compared to the pre-COVID-19 period. Impact of home confinement on myopia may be considered when future lockdown measures are being contemplated. (AU)


Assuntos
Humanos , Criança , Miopia/diagnóstico , Miopia/prevenção & controle , Comprimento Axial do Olho/crescimento & desenvolvimento , Comprimento Axial do Olho/patologia , Pandemias , Quarentena
19.
Vestn Oftalmol ; 140(1): 93-98, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38450472

RESUMO

Myopia and glaucoma are the leading causes of irreversible blindness in the world, and as the number of nearsighted people is predicted to increase sharply in the upcoming decades, an increase in combined pathology is expected. This article analyzes literature sources to assess the epidemiology of glaucoma and myopia both worldwide and in the Russian Federation, examine the anatomical changes of the eyeball associated with these diseases, and identify the diagnostic criteria that facilitate the verification of glaucoma when combined with myopia.


Assuntos
Glaucoma , Miopia , Humanos , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Glaucoma/etiologia , Miopia/complicações , Miopia/diagnóstico , Miopia/epidemiologia , Olho , Cegueira , Federação Russa/epidemiologia
20.
BMJ Open Ophthalmol ; 9(1)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429067

RESUMO

OBJECTIVE: This study investigated the agreement between objective wavefront-based refraction and subjective refraction in myopic children. It also assessed the impact of cyclopentolate and refraction levels on the agreement. METHODS: A total of 84 eyes of myopic children aged 6-13 years were included in the analysis. Non-cycloplegic and cycloplegic objective wavefront-based refraction were determined and cycloplegic subjective refraction was performed for each participant. The data were converted into spherical equivalent, J0 and J45, and Bland-Altman plots were used to analyse the agreement between methods. RESULTS: Linear functions were used to determine the dependency between the central myopic refractive error and the difference between the method of refraction (=bias). The influence of central myopia was not clinically relevant when analysing the agreement between wavefront results with and without cyclopentolate (comparison 1). The bias for wavefront-based minus subjective spherical equivalent refraction (comparison 2) was ≤-0.50 D (95% limits of agreement -0.010 D to -1.00 D) for myopia of -4.55 D and higher when cycloplegia was used (p<0.05). When no cyclopentolate was used for the wavefront-based refraction (comparison 3), the bias of -0.50 D (95% limits of agreement -0.020 D to -0.97 D) was already reached at a myopic error of -2.97 D. Both astigmatic components showed no clinically relevant bias. CONCLUSION: The spherical equivalent, measured without cycloplegic agents, led to more myopic measurements when wavefront-based refraction was used. The observed bias increased with the amount of myopic refractive error for comparisons 2 and 3, which needs to be considered when interpreting wavefront-refraction data. TRIAL REGISTRATION NUMBER: NCT05288335.


Assuntos
Miopia , Erros de Refração , Criança , Humanos , Midriáticos , Ciclopentolato , Erros de Refração/diagnóstico , Miopia/diagnóstico , Pupila